Language:English繁體中文Français

System Diagnostics

BYD ATTO 3 Won’t Charge: AC, DC and 12V Battery Diagnosis

The ATTO 3 handbook lists seven causes for a charger that connects and starts but does not charge the battery – and one of them is an over-discharged low-voltage battery. DC charging will not stop without a double unlock press inside three seconds, and the charge port locks itself again 30 seconds after unlocking.

GAC AION M8 PHEV High Voltage Shutdown: 355 V Rescue Data

The AION M8 is a plug-in hybrid, so the cut-zone map has to avoid a 56 litre fuel tank as well as a 355.2 V traction battery. Two-step isolation, a blue locking pin on the HV plug, and a 15 m storage radius – all from the official 22-page rescue manual.

GAC AION V High Voltage Shutdown: Rescue Data for Workshops

The second-generation AION V runs a 301.44 V or 351.68 V LFP pack and publishes two different main disabling method variants depending on region. Here are the numbers, the cutting limits and the towing rules a workshop needs before the car goes on a lift.

MG S5 EV Service Specifications: Coolant, Fuse and Torque Data

MG publishes more on the S5 EV than most Chinese brands – two separate coolant circuits with published capacities, a full alignment table, cold tyre pressures, and two fuse boxes with per-circuit amperage. What it does not publish is torque: 328,000 characters of owner’s manual contain a single Nm figure, and that one is the motor’s peak torque. Here is everything that is actually usable, and the boundary that tells you when to stop.

NETA X High Voltage Shutdown: 300V Rescue Sheet for Workshops

NETA publishes a 40-page emergency rescue manual for the NETA X – a 300V lithium-ion car – and it contains three numbers an independent workshop will not find anywhere else: the high voltage system re-energises about 60 seconds after an airbag-triggered automatic shutdown, you wait more than five minutes for capacitance discharge before touching anything, and a damaged pack is discharged by 90 hours of fresh water immersion followed by salt, never salt first. Here is the documented isolation procedure and the fire, submersion and storage rules around it.

Hongqi E-HS9 Fuse Box Locations: Six Boxes, No Published Ratings

The E-HS9 owner’s manual shows six fuse locations and tells you exactly how to open each one – then states that the distribution and amperage rating of the fuses must be confirmed by an authorised FAW Hongqi dealer. Here is what the manual does publish, the rule that forbids uprating a fuse, and how to tell an electrical fault from a job that should never leave the shop.

NIO EL6 Fuse Box Diagram: All Three Boxes and Ratings

The NIO EL6 owner’s manual publishes three complete fuse tables – the under-hood fuse box, the instrument cluster fuse box and the rear trunk fuse box – but almost nothing else electrical. Here are all three, transcribed, plus the cross-model trap: the same fuse number carries different ratings on different NIO models, so the table only means anything with the model attached.

GAC E8 Service Schedule: Official Intervals for Workshops

The GAC E8 is a range-extender, so its Warranty and Maintenance Manual carries two service systems at once: engine oil, filters, spark plugs and a fuel filter on one side, high voltage harnesses, traction battery checks and two separate coolant circuits on the other. Here is what the official regular maintenance schedule actually says, including the shortened intervals for harsh driving conditions.

VOYAH Courage High Voltage Shutdown: Rescue Sheet for Workshops

VOYAH publishes a 33-page Emergency Response Guide for the Courage, and it contains the numbers an independent workshop cannot get anywhere else for this platform: a 379.2 V LFP pack, the official main disabling order, the alternative cable-cut method and its catch, and a towing rule that forbids direct towing outright. Here is what it says, and where its authority stops.

MG4 EV High Voltage Shutdown: Safe Isolation for Workshops

MG publishes the isolation sequence for the MG4 EV, and it is short: immobilise, kill the 12V negative, then remove the manual service disconnect under the bonnet. What is not short is the list of things the same document tells you never to do — breaching the pack cover, parking a coolant-leaking car indoors, or assuming silence means dead.

BYD Coolant Type and Capacity: Every Current Model Compared

What BYD coolant type and capacity actually are, model by model, taken from all ten official English handbooks: four different spec names for one chemistry, freezing points that are not interchangeable, and why PHEV models have two separate circuits.

Tesla Model Y Won’t Charge: Charge Port System Diagnosis

Why a Model Y won’t charge is usually decided in the charge port assembly — latch, ECU, pin condition or door mechanism. Here is how the sub-systems break down and which order to test them in, with OEM correction codes and torque data.