The second-generation GAC AION V, the 2025 five-door model, publishes its high voltage figures openly: a 301.44 V or 351.68 V LFP pack mounted under the vehicle floor. For an independent workshop, the value of that official document is not that it teaches you how to repair the car. It is that it settles three things a hoist cannot wait for: how to isolate the car, where you may not cut or lift, and what the towing and storage red lines are. Everything below is taken from the English edition of the GAC AION emergency response guide, version 001, and the English rescue sheet issued with it.
Pack and stored energy: two voltages to remember
| Item | Figure | Where it comes from |
|---|---|---|
| Power battery voltage | 301.44 V / 351.68 V, two configurations | Rescue sheet and the stored energy chapter |
| Cell chemistry | LFP, located beneath the vehicle floor | Same chapters |
| Low voltage system | 12V battery sits in the front body; it feeds SRS, windows, door locks, the centre display and lamps, and it powers the high voltage contactor | Stored energy chapter |
| Rescue sheet stored figure | The sheet prints 850-950 g alongside the two voltages | Rescue sheet page 3 |
The guide repeats one line that matters more than the numbers: lack of engine noise does not mean the vehicle is off. Until the vehicle is fully shut down it can move silently or restart instantly.
Two variants of the main disabling method
The manual publishes two different isolation sequences depending on region, and using the wrong one leaves you working on a car that is still live:
| Region version | Isolation action |
|---|---|
| Europe | Pull the front body hood release handle twice to open and prop the hood. Wearing insulating gloves, disconnect the black low voltage water heater assembly connector to cut the high voltage |
| Non-Europe | Disconnect the low voltage battery negative cable first. Then, wearing insulating gloves, disconnect the black low voltage integrated electric drive assembly connector (1), then pull out the orange high voltage connector (2) to cut the high voltage |
Two supporting details are worth knowing before you need them: if the charger will not release, there is a manual charger unlocking cable in the front body, and the 12V negative terminal is secured by nuts that can be loosened with hand tools.
Against both variants stands the sentence the guide applies to the entire procedure: regardless of the disabling program used, always assume all high voltage components are live. The same section states plainly that you must not attempt to open the power battery.
Cutting and lifting limits: orange is forbidden, cyan is reinforced
- Cutting prohibited areas are marked in orange. High voltage, gas inflators and gas springs sit in those zones, so cutting or crushing them is prohibited.
- The vehicle’s high strength zones are marked in cyan, and those are the areas to cut with suitable tools such as a hydraulic cutter.
- High voltage cables are orange-yellow. Do not damage them with rescue tools, and treat them as live.
- Lifting: because the pack sits under the floor, do not compress the chassis area and do not use rescue tools on the power battery. Either can damage the pack or the high voltage cables.
- If battery pack coolant leaks, there is a thermal runaway risk. The guide’s instruction is to check pack temperature with an infrared thermal imager.
Fire and battery reignition: the numbers worth putting on the wall
| Situation | What the guide requires |
|---|---|
| Power battery fire | Extinguish with water; if the battery ignites, overheats or generates gas, cool it with a large amount of water |
| Handing the vehicle on | Only after at least one hour with no flames, smoke or high temperature |
| Temperature monitoring | Monitor pack temperature for at least 24 hours |
| Storage distance | Packs damaged by flood, fire or collision must be stored in the open, at least 50 feet (15 metres) from any exposed items |
| If water is unavailable | Use carbon dioxide, dry powder or other typical agents until water arrives; do not use water-based fire extinguishers |
| Combustion products | May include volatile organic compounds, hydrogen, carbon dioxide, carbon monoxide, soot and particles containing nickel, aluminium, lithium, copper, cobalt, plus hydrofluoric acid — full PPE including SCBA is mandatory |
Battery reignition is the phrase this document repeats more than any repair value, and it repeats it for a reason: an extinguished EV fire is not a finished incident.
Submerged vehicles: lift the front first
Electric shock risk is higher on a submerged vehicle and the pack may catch fire. The guide’s sequence is specific: during the rescue, lift the front of the vehicle to drain water from the vehicle and from the power battery, and after the vehicle is out, safely disconnect the high voltage following the disabling section. Full protective equipment for water rescue is a requirement, not a recommendation.
Towing and storage: all four wheels off the ground
- The drive motor generates electricity when the wheels turn, so during transportation all four wheels must be off the ground and the tyres must not rotate at any point. Overheating in extreme cases can set surrounding components on fire.
- A flatbed truck is recommended; if conditions are inadequate, a wheel-lifting truck can be used as needed.
- Only the towing methods shown in the manual’s illustrations 1, 2 and 3 may be used; methods 4, 5 and 6 are prohibited. Towing is for straight roads or routes without sharp turns, and no person may remain inside the vehicle.
- Where a flatbed cannot reach, a rigid connection may be used to move the car to a safe area, but speed must not exceed 5 km/h and long distance towing must be avoided.
- Pushing is only for short-distance traffic clearance. Pushing out of N can overheat the drive motor, and if the driver is not in the car the system may return the vehicle to P.
Two timers: ten minutes and ten seconds
- After a fire is extinguished, it may take 10 minutes for the high voltage circuit to power off.
- The SRS control unit has a backup supply that discharges in approximately 10 seconds. Do not touch the SRS control unit within 10 seconds of airbag or pretensioner deployment.
These two numbers are not the same kind of number. One tells you to wait, the other tells you to stay clear. Blur them together and you get the dangerous version of the story: the pack is down, so the SRS unit is safe to grab.
What this document does not give you
- It carries no repair procedures: no removal and installation steps, no fastener torques, no correction codes or flat rate times.
- It carries no wiring diagrams and no fault codes; diagnostics live at a different documentation level.
- Its purpose is rescue and safe handling, not workshop instructions. Use it to decide whether and how the car can be moved safely. Do not use it to quote a job or to guide assembly.
- The practical conclusion for an independent workshop: the public layer on this model is enough to approach and isolate the car safely, and not enough to complete high voltage removal and installation unaided. That is exactly the point where guided support or a qualified partner belongs.
Stuck on a Fault Code or a Locked Module?
Our technicians work with Chinese OEM diagnostic tools every day. Send us the VIN and the fault codes — we’ll tell you exactly what to check, in what order, and what it costs.
Need the Parts?
We source OEM and OEM-equivalent parts for Chinese EVs and ship worldwide — brake pads, coolant pumps, charge ports, sensors and more.
Source
Summarised and rewritten from the official English edition of the GAC AION Second-Generation AION V Emergency Response Guide (Version 001, 35 pages) and the accompanying English Emergency Rescue Sheet for the second generation AION V (Document No. 001, 4 pages). Voltages, stored figures, the region-specific disabling sequences, cutting and lifting restrictions, reignition monitoring durations, towing and storage distances, and the ten minute and ten second timers are all taken from those two documents. The official source entry point is gac-motor.com.