“The contactor is welded” is an expensive sentence
In a Tesla Model 3 pack, the main contactors connect and isolate the battery from the high voltage system. When one seizes – the manual’s word is seized, and the practical outcome is welded – the symptoms are all over the place: the car will not go into gear, HV is still present after unplugging, isolation faults appear, or nothing is reported at all and the car simply will not move.
Condemning a contactor is not a small decision, which is why Tesla publishes a page for it: HV Battery Contactor Seize Check, correction code 16309000, with no flat rate time on the page. It is not a timed operation. It is a decision procedure.
It has two levels, and the second only happens when the first clears. Run them in the wrong order and you reach the opposite conclusion.
Level one: is there more than 0.1 V across it
Set the meter to DC voltage and measure across the contactor terminals:
- A reading outside the range of -0.1 V to 0.1 V means the contactor is not seized – go on to the insulation measurements;
- A reading between -0.1 V and 0.1 V proves nothing on its own, so then switch the meter to resistance and measure again.
The logic is straightforward: a welded contactor is mechanically shorted, so the potential difference collapses towards zero. But zero potential difference can also mean both sides happen to sit at the same potential with the contactor properly open. Near-zero volts is grounds to keep testing, not grounds to condemn.
The next criterion is 1 MOhm: resistance across the terminals greater than 1 MOhm (1000 kOhm) means not seized; lower than 1 MOhm means it might be seized, and the instruction is to discontinue the procedure, replace that contactor, and then retest. The retest is part of the instruction, not an optional follow-up.
Level two: one table, two different verdicts
If level one clears, the next step is what actually separates “the pack is faulty” from “the contactor is faulty”. The page tabulates two resistance measurements, both against chassis ground, both passing at more than 1 MOhm – and failing with completely different meanings:
| Probe (positive lead) | Reference (negative lead) | Pass | Meaning of a fail, and the action |
|---|---|---|---|
| Battery positive (rear terminal of the positive contactor) | Chassis ground | > 1 MOhm | Resistance is low inside the pack – escalate a Toolbox session |
| B+ (LH probe opening) | Chassis ground | > 1 MOhm | Resistance is low at the contactor or ancillary bay – replace that contactor and retest |
That contrast is the whole article in one table. Same test, same threshold, and the probe position decides whether this becomes a contactor replacement or an escalation. Probe the pack side and fail, and you are reporting an internal pack problem. Probe the B+ opening and fail, and you are replacing a part.
The negative contactor runs the identical two-level sequence, with the measurement points changed to battery negative (LH terminal of the negative contactor) and B- (RH probe opening). The split verdict is the same: internal pack problem goes to Toolbox, contactor or ancillary bay problem means replace and retest.
The tooling rules are strict on this page
- Specified equipment: Fluke 1587 FC insulation multimeter, part number 1076921-00-A. Not a general purpose meter.
- The meter and leads must handle at least 500 V DC.
- Test the leads first. Touch the probe tips together on resistance: if the meter shows more than 0.2 ohm, the leads are defective and must be replaced – do not use them.
- HV insulating gloves rated class 0 (1000 V) minimum, worn throughout, per tech note TN-15-92-003.
- Remove all jewellery and metal before starting: watches, bracelets, rings, necklaces, earrings, ID tags, piercings; and empty pockets of keys, coins, pens, tools and fasteners.
- The page states that only technicians who have completed all required certification courses may perform it, and that Tesla recommends third party technicians undergo equivalent training.
The lead check is the step most people skip. A 0.2 ohm threshold looks trivial until you consider what a half-broken lead does to the rest of the procedure: it can manufacture a false “less than 1 MOhm”, which becomes an unnecessary contactor replacement or, worse, an unnecessary pack escalation.
This page is one stop inside the disablement sequence
The procedure opens by having you remove the ancillary bay cover and closes by telling you to return to the Vehicle HV Disablement Procedure. The contactor check is a station on the disablement route, not a standalone job.
That is also why it carries no FRT. Its time is accounted inside the disablement procedure, and the check itself is a measure, judge, replace, retest loop. Quote it as a standalone 0.x hour task and you will miss the cover coming off twice.
Common mistakes and misreads
- Insulation testing with a general purpose meter. Neither the input impedance nor the range is adequate; readings above 1 MOhm mean nothing.
- Condemning on near-zero volts. The order is voltage first, resistance second – near zero volts only means keep measuring.
- Replacing a contactor on a sub-1 MOhm reading without locating the fault. Probe position decides whether it is the pack or the contactor and ancillary bay.
- Not retesting after replacement. The page says “and then retest” in both places.
- Ignoring an existing isolation alert. If isolation alerts are already logged, every reading on this page is taken on a faulty system and cannot be used as-is.
Where the manual tells you to stop
Stop conditions appear twice on this page and both are written by the manual itself: a voltage measurement greater than 10 V in the adjacent disablement step means stop work and reach out to Service Engineering; and a resistance result that points inside the pack is not a contactor replacement – it is a Toolbox session to escalate.
The second one matters most. Internal pack isolation failure is not fixed by bolting a new contactor to the outside of it. By writing the action as “escalate”, the manual is telling you that this is a factory-level problem. The correct move for an independent shop is to stop and issue a report with the readings attached, not to keep opening things.
The three questions worth asking before you take the job
- Do I have an insulation multimeter – not a general meter – with leads I have actually tested?
- Can I read and interpret the BMS alerts present on this car?
- If the result points inside the pack, do I have a route to escalate the finding?
Three yeses and this job is worth taking, and you will do it more accurately than most – because what you hand over is not “we changed a contactor” but a set of readings with probe positions, thresholds and times attached. That is the kind of report that brings the next job back.
If you are unsure about questions two or three, a remote review of the readings will usually cost less than opening the ancillary bay on a guess. Send us the alerts, the probe points and the numbers, and we will read them with you.