A coolant leak you cannot see, and a 2-minute test that finds it
Every workshop knows the car that loses coolant and leaves nothing on the floor. On a Model 3 there is one circuit where that happens and no external evidence exists: the coolant jacket inside the high-voltage battery enclosure, in the ancillary bay. Tesla’s answer is a dedicated procedure, correction code 16200200 at 2.16 hours, and the whole verdict rests on one number – a pressure drop of 0.35 PSI or less over a 2-minute hold at 50 PSI.
This article is about the diagnosis, not the teardown: what the test proves, what it does not prove, and the three places where a shop can get a false pass or a false fail.
Why the pack is part of the cooling circuit at all
On a Model 3 the traction battery is liquid cooled, and the coolant enters and leaves through fittings on the underside of the ancillary bay – one on the right-hand side for the rear powertrain supply hose, one on the left for the rear drive unit inverter inlet hose. Between them sits a coolant jacket inside the pack. If that jacket leaks, coolant goes into the enclosure, not onto the road. There is no drip, no smell you can localise, and no external stain. The only symptoms are a slowly falling level and, eventually, insulation faults.
That is the diagnostic fork this procedure exists to resolve. A car losing coolant with nothing visible outside has, broadly, four candidates: the bottle and its o-ring, the chiller, the supermanifold joints, and the pack jacket. The first three are cheap and accessible. The fourth is a battery-out job. The ancillary bay coolant leak test is how you decide which side of that line you are on before you start removing parts.
What the test actually does
It isolates the pack’s coolant volume, then pressurises it with dry shop air through a regulator and holds it, watching the digital pressure gauge for two minutes. No coolant is added, no vacuum is pulled. It is a decay test on a sealed volume, and it answers exactly one question: is the coolant path inside that enclosure holding pressure?
The equipment list is short but specific. You need the drive unit pressure test fixture 1053600-00-C, the coolant leak test adapters for Model 3 1132185-00-B, and plugs from the coolant drain and fill adapter kit 1133843-00-A. A generic cooling system pressure tester with a cone adapter is not a substitute: the fittings on the underside of the ancillary bay are a specific male form and the test is run at a pressure a hand pump will struggle to hold steady for two minutes.
The sequence, and the three numbers in it
- Disconnect 12V power. Remove the mid aero shield panel and the rear HV battery skid plate.
- Put a drain under the rear RH side of the pack. Release the clip, disconnect the rear powertrain supply hose from the RH underside of the ancillary bay, plug the female fitting and let the pack drain.
- Connect the coolant pressure test adapter to the male fitting on the RH underside.
- Zero the gauge. Open valves P1 (inlet) and P2 (outlet) on the fixture, power the digital gauge on, hold RESET/CLEAR until it reads zero. This step was added in the 2026-01-27 revision – the whole revision is that one line, which tells you people were recording drops that were really zero offsets.
- Close both valves, back the regulator knob off fully counter-clockwise, connect shop air to the right side of the fixture, open P1, and set 50 PSI. The page allows 48 or 49 PSI if 50 is not attainable – it does not allow you to run the test at whatever the shop compressor gives you.
- Connect the outlet hose to the left side of the fixture, then to the adapter. Hand-tighten both.
- Set a timer for 2 minutes, slowly open P2, and start it. Monitor the drain and control splashing.
- When the timer ends, close P2, disconnect the outlet hose, record the ending pressure, and subtract it from the starting pressure.
Then the decision: a difference of 0.35 PSI or less passes. More than 0.35 PSI does not fail the pack immediately – it sends you to check the hoses, adapters and plug fittings, then re-run the hold. Only if it is still over 0.35 PSI after that do you escalate to Service Engineering.
The three ways to get the wrong answer
1. A gauge that was not zeroed. A digital gauge with a stored offset will show a drop that does not exist, or hide one that does. The page added the zeroing step in January 2026 for a reason. Zero it with both valves open and no pressure, every time.
2. An adapter that is leaking instead of the pack. This is why the fail path exists at all: check hoses, adapters and plug fittings and repeat before you condemn anything. A hand-tightened fitting at 50 PSI will pass two minutes when it is right and will not when it is cross-threaded. The coolant pressure test adapter and the plug on the left-hand fitting are the two joints most likely to be the actual leak.
3. Testing a pack that is still full of coolant. The procedure drains the pack first, through the RH fitting, with a drain positioned under the pack. If you skip the drain, you are pressurising a volume that is partly liquid, and the decay curve means nothing.
What a pass does and does not prove
A pass proves the coolant volume inside the enclosure holds 50 PSI for two minutes. It does not prove the level sensor is telling the truth, it does not prove the chiller is sound, and it says nothing about the rest of the thermal loop – which is why the page finishes with a vacuum refill of the cooling system rather than a top-up. Once you have had the circuit open and drained the pack, the loop has to be refilled under vacuum and purged, exactly as after any other thermal repair.
Practically, a pass is the moment to go back to the cheap candidates: bottle o-ring, chiller, supermanifold joints. A fail is the moment to stop, because the next step involves the pack, and that is not a decision to make at 5 pm on a Friday.
Two shortcuts worth knowing
The page opens with a conditional: if the power conversion system is being installed and the ancillary bay coolant drain has already been performed, begin the test at step 35. In other words, this test is designed to be run as part of a bigger job, after the drain is already open – it is not always a standalone 2.16 hours. If you are already in there, the marginal cost is small; if you are not, you are paying for the aero shields, the skid plate, the drain and the refill.
The second is the order at the end: refit the skid plate and mid aero shield, reconnect 12V, then vacuum refill the cooling system. Reconnecting 12V before the thermal loop is refilled means the car can run a routine against a dry circuit. Sequence matters more than speed here.
When to hand it off
If the drop stays over 0.35 PSI on a second hold with new adapters and checked fittings, do not open the pack to look. That is a decision about a high-voltage enclosure, and the honest answer for most independent shops is that the test is where their involvement ends and the referral begins. Running the test yourself is still the right call: it converts “we think it might be the battery” into a documented number, and a documented number is what a customer will pay for and what a specialist will accept.