Language:English繁體中文Français

Tesla Model 3 Heat Pump Flush: When Oil Quantity Is Unknown

The page exists for one situation: nobody knows how much oil left the system

On a heat pump Model 3, the A/C system eventually reaches a case with no clean answer. Refrigerant leaked out, or a compressor was replaced, or a line was opened after an impact. You recover what is left and the oil you take out does not match any expected figure. Top it up and you risk overfilling; leave it and you risk underfilling. Both end with a seized compressor a few months later.

Tesla’s answer for that case is a dedicated procedure – A/C Refrigerant (Heat Pump) (Unknown Oil Quantity or System Flush), correction code 18200112, FRT 1.07 hours. The logic is simple: if the quantity is unknown, clean the system and put a known quantity back.

Three numbers to hold on to

Item Figure printed in the manual
Correction code for this procedure 18200112, 1.07 hours
Code that must be added separately 18200102, A/C Refrigerant (Recovery and Recharge)
Flush machine run time Approximately 90 minutes, with at least 3.2 kg of refrigerant in the machine tank

1.07 hours is 64 minutes. The flush alone occupies the machine for 90. Put side by side, those two figures are the most commercially important thing on the page: whoever quotes 1.07 hours is quoting the paperwork, not the bay.

When a flush is the right call and a top-up is not

The recovery step carries the decision rule. Record the amount of refrigerant and the amount of oil recovered. If the drained oil level increased by more than 1.01 oz (30 mL), the manual sends you to the drained oil loss chart, Article 353700.

A working sequence for a shop:

  1. Recover and weigh. Log refrigerant and oil separately – without the numbers there is no decision to make.
  2. Oil quantity above expectation goes to Article 353700 before anything else.
  3. A replaced compressor, a replaced condenser, a line that sat open, or an unknown history: flush. Do not gamble on the top-up quantity.
  4. Seals only, system never opened: standard recovery and recharge under 18200102. No flush needed.

The desiccant bag has to come out, and that rule is recent

The revision list is blunt about it: 2026-04-07 added the steps to remove the desiccant bag before flushing and to replace it afterwards, and 2026-04-06 added flush procedures for each type of machine.

Which means every copy of this procedure that predates April 2026 – the versions circulating in forums, in training videos, in third-party compilations – is missing the desiccant step. Flushing through a saturated desiccant puts the water and debris straight back into the circuit. It is the single most valuable warning on the page.

After removing the bag, the manual has you fit the old cap into the accumulator and refit the snap ring, checking that the ring is properly seated in the accumulator groove. A ring that is not seated gets pushed out by flush pressure.

Two machines are supported, and generic fittings will not do

The special tools list is specific:

  • 1600279-00-A, A/C Oil Flush Adapter Set for Model Y, or 1600279-N0-B for heat pump vehicles with unknown oil conditions.
  • 1711245-00-A, Snap-on Ecotechnics dual gas A/C machine including the flush adapter kit for R134a and R1234yf.
  • 1120026-01-A, WAECO ASC5500 RPA A/C service machine.

The adapters go onto the supermanifold-to-compressor line and are attached with the two 13 mm nuts taken off the compressor. That detail matters: a generic flush kit does not fit that line, because the adapter is matched to it.

How the two machines differ in use

Snap-on: run the full flush from the machine menu (Menu, 4, OK, OK). The procedure states approximately 90 minutes and a minimum of 3.2 kg of refrigerant in the tank.

WAECO: red pressure line to the high side, blue line from the flush kit to the low side; the kit bolts to the machine with two 8 mm bolts and one Nyloc nut. Then a maintenance rule that gets forgotten: mark the liquid line filter drier with a paint marker before every flush and replace it after ten flushes. The filter is PR052FM, the copper sealing rings are replaced, the old ring must come out first, and it is hand tight only because the line is copper.

That ten-flush interval is machine maintenance, not vehicle repair, and it decides the quality of your next job. Very few independent shops track it.

Prerequisites: this is not “open the system and flush”

The first half of the page is an authorisation and safety chain:

  • Unlock the gateway, enter Service Mode on the touchscreen, and run Thermal, Refrigerant System, Start Thermal Fill Drain (Refrigerant only).
  • Remove the underhood storage unit, move the seats forward, disconnect 12V/LV power, remove the 2nd row lower seat cushion.
  • Perform vehicle HV disablement.
  • Wear a face shield, heat-resistant gloves, rubber boots and a waterproof apron. R134a and R1234yf are dangerous liquids.
  • Remove the low side and high side manifold nuts, 22 Nm each, 13 mm, and move the pipes aside. The compressor HV harness bracket bolt is 9 Nm at 13 mm and the ground strap bolt is 7 Nm at T25.

The compressor HV connector is a three stage locking type: move the black locking tab to position 1, use a 45 degree pick to push down on position 2 while prying up on position 3, then separate. The manual supplies three photographs because getting the order wrong breaks the lock. The compressor logic connector is the opposite habit – the red tab is pulled, never pushed.

Certification and the limit of the page itself

Two sentences sit at the top of the procedure:

  • Only technicians who have completed all required certification courses may perform it, and Tesla recommends third party technicians undergo equivalent training.
  • In EMEA, on top of local A/C or F-gas certification, technicians are required to complete Air Conditioning Safety Essentials before working on thermal management and A/C systems.

The page also labels itself a DRAFT: validated, but warnings and cautions may be missing. For an independent workshop the practical reading is that the barrier here is not the price of a machine, it is certification and procedure control.

When to hand it over

Three clean lines: no local refrigerant certification, no correct flush adapter for the line, or evidence of internal compressor wear – metal in the oil, or an unexplained increase in recovered oil. The third case does not respond to flushing at all; the correct repair is compressor and filter replacement, not a wash and a recharge.

The part worth remembering

What this page really provides is a standard answer for “unknown”: flush it, remove and renew the desiccant bag, track the filter drier by flush count, and put a known quantity back. The 1.07 hours buys knowledge; the 90 minutes buys bay time. Quote 18200102 as its own line and put the machine time in the estimate, and the price stops needing an apology.

Stuck on a Fault Code or a Locked Module?

Our technicians work with Chinese OEM diagnostic tools every day. Send us the VIN and the fault codes — we’ll tell you exactly what to check, in what order, and what it costs.

→ Get Remote Repair Support

Need the Parts?

We source OEM and OEM-equivalent parts for Chinese EVs and ship worldwide — brake pads, coolant pumps, charge ports, sensors and more.

→ Browse Parts

Summarised and rewritten from the Tesla Model 3 service manual page “A/C Refrigerant (Heat Pump) (Unknown Oil Quantity or System Flush)”, correction code 18200112, FRT 1.07, revision dated 2026-08-09. All figures, part numbers and routine names are quoted from that page.