Language:English繁體中文Français

Tesla Model 3 A/C Compressor and Supermanifold: 1.92 Hours

Start with the least intuitive line on the page

Correction code 18204012 pays 1.92 hours to replace the compressor, the supermanifold and the line between them. The same page also carries a note that almost nobody reads:

Overlap from A/C system flush procedure — subtract time spent on other operations while waiting for the A/C system flush; fast flush is 40 minutes, full flush is 1 hour and 40 minutes.

Read those two numbers together with the FRT. A full flush alone runs 100 minutes of machine time inside a 115 minute job. The 1.92 only closes if you are removing and installing other parts while the machine is running. A shop that flushes first and then starts work will overrun this job every single time — not because the technician is slow, but because the work was sequenced wrong.

There is also a second correction code that must be added

The page states that this procedure requires the A/C refrigerant recovery and recharge procedure, and that if it has not been added automatically, you must add correction code 18200102 as a separate correction within the same activity. Refrigerant is not inside the 1.92.

Quote the two lines separately and a customer asks why a compressor has two labour charges. Quote them as one and you have promised recovery, vacuum, leak test and recharge for 1.92 hours.

Six thermal alerts decide 40 minutes or 100 minutes

This is the decision point on the page. Once the vehicle is in Service Mode, open the alert icon and check for these six:

  • VCFRONT_a161_compressorSelfFault
  • VCFRONT_a163_compressorDisabledFSR
  • VCFRONT_a460_hardIsentropicTdFailed
  • VCFRONT_a467_lowPowerIndexFlagged
  • VCFRONT_a531_lowPowerIndexFlaggedUserFacing
  • VCFRONT_a543_compressorLowFlowDeliveryDetected

The rule is binary, with no middle ground:

  • Any one of them present — you must perform a full flush later, roughly 1 hour 40 minutes.
  • None present — perform a fast flush, roughly 40 minutes.

You have to make that call before committing the bay, because it decides whether the job fits in the day. An alert means the compressor failed mechanically and pushed debris through the circuit — which is exactly why this procedure exists. It uses a debris flush adapter (1838504-C0-A, -E0-A or -N0-A) to flush the supermanifold-to-HVAC line and the HVAC assembly so both can be reused instead of replaced. If you only have the older 1838504-00-B adapter, the manual sends you to the separate compressor-and-supermanifold procedure instead.

Machines and consumables are the gate, not the wrenches

  • 1600279-00-A — A/C oil flush adapter set
  • 1838504-C0-A / E0-A / N0-A — debris flush adapter
  • 1711245-00-A — Snap-On Ecotechnics dual gas A/C machine, with R134a and R1234yf flush adapter kits
  • 1120026-01-A — WAECO ASC5500 RPA A/C service machine

Two consumable limits hide in the notes and both look like filler until they stop you. Running the system flush on the Snap-On machine needs a minimum of 3.2 kg of refrigerant in the tank. Flushing the HVAC case on the WAECO ASC 5500G RPA needs a minimum of 6 kg. Short on gas and the machine simply will not start — that is not a technical problem, it is a stocking problem, and it parks a car in your bay for a day.

Torque: mostly low voltage hardware, but two figures changed

Fastener Torque
Shock tower brace to body 55 Nm (two bolts) and 62 Nm (one)
Supermanifold to shock tower brace 31 Nm
Compressor to shock tower brace 31 Nm
Supermanifold to HVAC A/C line (13 mm nut) 36 Nm
A/C line to HVAC assembly (10 mm, x2) 28 Nm
Compressor bracket to compressor (10 mm, x3) 9 Nm
Harness bracket to compressor 9 Nm
Fittings on the compressor 22 Nm

The revision dated 2025-10-27 changed two of these: the HVAC side of the A/C line went from 22 Nm to 28 Nm, and the supermanifold side from 27 Nm to 36 Nm. They are the two ends of the same pipe, so old documentation leaves both joints under-torqued. Note also that the shock tower brace uses 55, 55 and 62 — not three equal values.

Three software steps after the hardware is back

  1. Compressor type. On firmware 2026.2.3 or later (NA/EMEA) or 2025.44.32 or later (APAC), use Thermal → Actions → Configure Compressor and run the routine. On earlier firmware, go to Thermal → Actions → Thermal Configurations → compressorType and select the correct type. Then check the Gateway configuration for compressorType and confirm it reads as intended. If the routine fails, the manual points to Toolbox article 5696900.
  2. Giga Berlin vehicles only — also set refrigACLineType by part number: 1502020-00-B or newer gives CONTI_LIMITED; 1625910-00-C or -D gives SAAA_LIMITED; 1625910-00-E or newer gives UNLIMITED; 1807596-XX-X gives UNLIMITED.
  3. Reinstall the firmware, then run the A/C vacuum leak test, the refrigerant recharge and the cooling system vacuum refill.

The first step was rewritten on 2026-04-07. The firmware reinstall is the one that gets skipped, and a skipped reinstall presents later as “the new compressor has failed too”.

Two field details straight out of the revision log

  • Coolant temperature sensor connectors do not always match. Before the next two steps, inspect the coolant hose temperature sensors and their connectors. On vehicles with the earlier sensor, the new supermanifold connectors may not fit, and the connector cover has to be swapped over from the old part. The manual puts that check before the supermanifold comes out precisely so you do not discover it on installation.
  • The 1.92 assumes the whole chain. Underhood storage unit, front aero shield, fresh intake duct, HV disablement, refrigerant recovery, three coolant hoses off with three male plugs into the supermanifold ports — all inside the FRT, none of it stackable.

When to hand it over

This is not a “depends on the day” job; it is decided by equipment. No dual gas recovery machine, no debris flush adapter, less than 3.2 kg in the tank, and you cannot run the flush at all. Without high voltage certification the disablement step stops you earlier still. Conversely, if the equipment is present and only the procedure is unfamiliar, the six alert identifiers, the two changed torque figures and the three configuration steps are the entire difficulty of the job.

One commercial note. When a customer says the air conditioning is not cold, do not open with 1.92. Run the recovery and recharge path first — a large share of these cars stop at 18200102 and never need the compressor. Treating 1.92 as the conclusion rather than the last resort is the most expensive habit in this corner of the workshop.

Stuck on a Fault Code or a Locked Module?

Our technicians work with Chinese OEM diagnostic tools every day. Send us the VIN and the fault codes — we’ll tell you exactly what to check, in what order, and what it costs.

→ Get Remote Repair Support

Need the Parts?

We source OEM and OEM-equivalent parts for Chinese EVs and ship worldwide — brake pads, coolant pumps, charge ports, sensors and more.

→ Browse Parts

Summarised and rewritten from the Tesla Model 3 service manual, A/C Compressor, Supermanifold and Compressor to Supermanifold A/C Line (Heat Pump) (Remove and Replace), correction code 18204012 / 1.92 h, revisions through 2026-07-03. Alert identifiers, torque values, flush durations, refrigerant quantities, configuration values and tool part numbers are quoted from that page. Confirm revisions on the page before use.

WhatsApp Support
Scroll to Top