First decide which “will not charge” you are looking at
When a customer says a JETOUR T2 i-DM won’t charge, there are four different fault surfaces hiding under that sentence: the car’s charge port lamp does nothing, the lamp is red, the charging box reports a fault, or charging starts and then stops on its own. The owner’s manual treats these as four different paths, not one checklist. So the first move is not a meter, it is reading lamps.
There are two lamp groups and they answer different questions: the indicator on the vehicle’s charge port, and the three indicators on the portable charging box. Mixing them up produces confident wrong answers.
The vehicle side: three states only
- Flashes green — charging in progress
- Remains on green — charging complete
- Remains on red — slow charging fault
That charging port indicator distinguishes exactly three things: charging, complete, slow-charge fault. It never tells you whether the problem is the car or the supply. Once it is red, the next thing to read is the box.
Three lamps on the charging box, nine named conditions
The charging box carries an operating/power indicator, a charging indicator (green) and a malfunctioning indicator (yellow). The manual turns their combinations into nine control box indicators conditions, in this order:
- Initial state
- Waiting for charging mode
- Normal charging
- Charging completed
- Grounded malfunction
- Overvoltage / undervoltage
- Over-temperature malfunction
- Leakage malfunction
- Overcurrent malfunction
The last five are the fault rows, and the real value of the table is that it sorts the fault into a class. Grounding, supply voltage, temperature, leakage and overcurrent are five independent causes, not one vague “charging is broken”. For an independent workshop, the practical use is to separate responsibility before touching anything: is this grid side, environment side, or vehicle side? If none of the first four rows is reached, the box never entered the charging sequence at all.
The manual then says, in the next paragraph: do not attempt to remove or repair the control box, and if these malfunctions occur, contact a Jetour authorised service station.
The troubleshooting table has four rows, and all four are owner level
| Complaint | What the manual asks you to check |
|---|---|
| Unable to charge | Observe indicator state against the table; check grounding is good; check supply voltage is normal; check the vehicle connection is normal |
| Intermittent charging | Observe indicator state; check the 220 V AC supply is stable; check whether temperature is too high |
| Power on trip during charging | Check grounding; check whether the device is short circuited; check whether the total power of all electrical equipment is too high |
| Malfunction every time power is applied | Unplug the three-pin plug and the gun, then insert and unplug again; if it persists, contact an authorised station immediately |
Read the third row carefully. “Power on trip” means the house breaker tripped, not that the car logged a fault. That is extraordinarily common in the field, and it has nothing to do with the vehicle: poor grounding, an internal short in the charging box, or a high-draw appliance on the same circuit. The row is the manual’s own argument for not dismantling the car yet.
The document gives you no measurable quantity
This is the hard boundary of this vehicle’s documentation. Across the 288 page T2 i-DM owner’s manual there is no voltage, resistance, current or insulation threshold anywhere in the charging chapters, and no fault code list at all — a scan of the entire JETOUR English corpus returns zero hits for DTC. What it provides is lamp states, a classification of symptoms, and an instruction to call the dealer.
For an independent workshop, that leaves exactly four things that can actually be closed:
- Verify the supply side: 220 V stability, grounding, other loads on the circuit
- Verify the vehicle connection: gun fully latched, no debris or standing water in the inlet
- Read the lamps and classify the fault: grounding, voltage, temperature, leakage, overcurrent
- Decide whether it has to be referred out
Everything beyond that needs factory diagnostic equipment and thresholds the manual never publishes.
The vehicle connection: three field details people miss
- The gun latch follows the door locks. Lock the car and the gun locks; unlock the doors and it unlocks; if nobody acts within a few minutes it re-locks, and you then have to press the key unlock button again before it will release. A fair share of “the gun will not come out” calls stop here.
- Never force the gun past debris or water. The DC inlet is called out specifically: standing water must be cleared and the inlet dried with a hair dryer, otherwise the result is an insulation fault.
- A frozen inlet must be thawed — a hair dryer is the manual’s own suggestion. Forcing the gun in causes a malfunction.
One prohibition runs through the whole chapter: do not close the charge port door while the port cover is open, or the charging device can be damaged.
The emergency release, and the order that matters
There is a mechanical release for a gun that will not come out: confirm the vehicle is not charging, open the tailgate, lift the luggage compartment carpet, take out the spare tool box, then pull the release cable. Two limits come with it. The cable is only for cases where the normal method fails, and continuous use damages the cable or the charging device. And the order is not negotiable — pull the cable before attempting to remove the gun, never while pulling, because doing it the other way is an electric shock risk.
External discharging is not charging, but it gets reported as charging
This vehicle supports external discharging through a supplied discharge device rated 220 V / 16 A with a maximum discharge power of 3.3 kW. A meaningful share of “the charge port does nothing” complaints are a customer who was trying to draw power out, or who never exited the discharge state. The discharge sequence is different from the charging sequence: confirm the external connection, take out the discharge gun, open the port cover and the slow charge port protective cover, insert the gun and lock it.
One plug-in hybrid rule is worth repeating because it catches people out: refuelling and charging cannot be performed at the same time. The fuel tank is 70 L, and the rescue data in the same manual lists a lithium iron phosphate pack rated 350.56 V at 52.5 Ah.
When to hand it over
Four hard lines:
- The lamp combination lands on leakage or overcurrent — both reach the high voltage side, and the manual explicitly forbids opening the control box.
- A fault on every power-up that survives a re-plug — the manual’s own instruction is to contact an authorised station.
- Any collision, wading or event that may have damaged the high voltage system — the manual routes that to an authorised station for inspection.
- The cluster shows the high voltage insulation indicator, at either the reduced or the seriously reduced level — both point to an authorised station, and neither comes with a threshold you could measure against.
Conversely, as long as the investigation stays on the supply side, the connection side or the environment side, an independent workshop can close this cleanly. When it does, put the lamp combination and the four checks on the job card. That record is the only thing that later proves the vehicle was not blamed for a wall socket.
Stuck on a Fault Code or a Locked Module?
Our technicians work with Chinese OEM diagnostic tools every day. Send us the VIN and the fault codes — we’ll tell you exactly what to check, in what order, and what it costs.
Need the Parts?
We source OEM and OEM-equivalent parts for Chinese EVs and ship worldwide — brake pads, coolant pumps, charge ports, sensors and more.
Summarised and rewritten from the JETOUR T2 i-DM Owners Manual (EN-MY, 20260117 edition): chapter 4, pp.144-155 for charging operation, control box indicators and the malfunction table; chapter 6, pp.239-240 for the rescue data. Condition names, the 3.3 kW discharge limit, the 220 V / 16 A rating and the pack figures are quoted from those pages. The manual publishes no diagnostic thresholds for the charging circuit, so do not substitute assumed values.