The 0.12 hour step that decides a four figure decision
When a Model 3 or Model Y arrives losing coolant with no visible puddle, the expensive question is whether the
drive unit is breached. The manual’s answer is a pressure test that is published at
correction code 40202010, 0.12 hours – twelve minutes of labour – and it is the cheapest thing in
the whole diagnostic chain. This article is about running it properly, because the pass/fail logic is where shops
get it wrong in both directions.
What the test is actually testing
The inverter and the drive unit share the same coolant path. The test isolates that path, pressurises it through
the coolant ports at the top and bottom of the inverter, and then watches whether the pressure holds. It does not
test the whole cooling system, and it does not test the battery pack. It answers one question: is the coolant
circuit through this drive unit leaking internally?
Four part numbers are needed, and they are the reason many independent shops cannot do this in-house:
- 1053600-00-C – Drive Unit Pressure Test Fixture
- 1132185-00-B – Kit, Coolant Leak Test Adapters, Model 3
- 1133843-00-A – Kit, Coolant Drain & Fill Adapters, M3
- 1135762-00-A – Kit, Service Plug, Cooling Hose, Model 3
That is a fixture plus three adapter kits, for one twelve minute test. Which is exactly the commercial point:
the shop that owns the fixtures can run this on every coolant complaint, and the shop that does not will keep
guessing at drive units.
Test setup, step by step
- Disconnect 12V power. Remove the mid aero shield panel. Position a coolant drain under the inverter.
- Disconnect the coolant outlet hose at the top of the inverter. Plug the female fitting of the hose, then
connect the coolant pressure test adapter to the inverter. - Connect the drive unit pressure test fixture to the adapter. Close both valves – P1 (inlet) and P2 (outlet) –
and connect the compressed air supply. - Fully close the regulator, then open P1. Set the regulator to 26 psi.
- Disconnect the coolant inlet hose at the bottom of the inverter, plug the hose fitting and let the inverter
drain. Connect the drain adapter to the bottom of the inverter and run its tube to the drain. - Slowly open P2 to speed the drain, then close P2. Swap the drain adapter for the pressure test adapter plug.
Open P2 again and allow at least 45 seconds for the pressure to stabilise back to 26 psi. That 45 seconds is not
optional – reading the gauge before it settles is how a good drive unit gets condemned.
The pass/fail rule, and the retest loop
Close P1, record the starting pressure, start a four minute timer, then record the ending pressure. Subtract
the end from the start.
- 0.2 psi or less – the drive unit passes. Continue the procedure.
- More than 0.2 psi – do not condemn anything yet. Check the hose, the adapter and the plug
fittings, close P2, open P1, recheck the regulator pressure, then retest from the stabilisation step. Only if the
second test is still over 0.2 psi does the procedure send you to the manufacturer’s internal guidance on the
next step.
This retest loop is the most useful thing on the page. A 0.2 psi drop over four minutes is small enough that a
slightly loose adapter fitting will produce it on a perfectly healthy drive unit. The manual’s own order –
fittings first, part second – is the same order we would give any technician chasing an unexplained coolant loss,
and it is the opposite of what happens in most shops under time pressure.
Closing out
Disconnect the air supply, open P1, remove the fixture and the adapters, then reconnect both coolant hoses.
The manual adds a caution here that deserves to be read twice: perform a push-pull test to verify
the hose is fully seated. Then remove the drain, install the mid aero shield, reconnect 12V, and perform a
vacuum refill of the cooling system.
That last step is the one that gets skipped on a “quick test” ticket, and it is the one that leaves air in the
system. Vacuum refill, not a top-up through the bottle.
Where the diagnosis goes next
If the drive unit holds 26 psi for four minutes, the coolant loss is somewhere else in the system, and the
reasonable next steps are the joints, the coolant bottle, the chiller and heater circuits, and the battery pack
side – in that order of cost. If it fails, and fails again after the fittings are rechecked, you have a breached
drive unit and a materially different conversation with the customer.
Either way, one twelve minute test has moved the diagnosis from opinion to measurement. For an independent
workshop, that is worth quoting as its own line item rather than burying it in a “coolant system inspection”
hour.
When to send it out
Without the pressure fixture and the three adapter kits, this test cannot be reproduced faithfully with generic
tooling – the adapters exist because the inverter ports are not a standard size. A shop in that position has three
honest options: buy the fixtures and make the test a standing offer, sublet the test, or replace parts on
suspicion. Only one of those is a business model. Remote support helps most with the interpretation – whether a
0.2 psi drift is a fitting or a housing – and with deciding what to quote once the number is in.
Stuck on a Fault Code or a Locked Module?
Our technicians work with Chinese OEM diagnostic tools every day. Send us the VIN and the fault codes — we’ll tell you exactly what to check, in what order, and what it costs.
Need the Parts?
We source OEM and OEM-equivalent parts for Chinese EVs and ship worldwide — brake pads, coolant pumps, charge ports, sensors and more.
Summarised and rewritten from the Tesla Model 3 service documentation, Inverter Coolant Leak Test,
correction code 40202010 / 0.12 h, revision dated 2026-08-09. Test pressures, tolerances, part numbers and
timings are quoted as printed in the source.