A Tesla Model Y low-voltage battery is not one part with one procedure. The service manual covers two different batteries under the same page title: a lead acid battery and a 16V lithium-ion (Li-Ion) battery. They carry different correction codes, different removal paths and different closeout routines. The single most expensive mistake an independent shop can make on this job is to quote it before knowing which one is in the car.
Two chemistries, two correction codes, one labour time
Lead acid vehicles use correction code 17011202 at 0.18 hours. Li-Ion vehicles use 17011232, also at 0.18 hours. The time is identical, the code is not, and a work order quoting the wrong one describes a job that does not exist for that car.
The manual gives an explicit way to tell them apart (a note added on 2025-11-14): touch Controls > Software > Additional Vehicle Information. Do not guess from model year and do not judge by the shape of the box under the hood.
Torque: two rows, and the second row splits by build
- Lead acid: positive and negative cable nuts to the battery terminal at 6 Nm (4.4 lb-ft), 10 mm deep socket, hardware reusable.
- Li-Ion: the three bolts that attach the battery to the bracket at 6 Nm (4.4 lb-ft), 8 mm socket. Early production vehicles use M6 bolts with a 10 mm head, and those are torqued to 10 Nm.
Same bolt, two values, and the deciding factor is the bolt head size rather than the model year. This is the easiest number in the whole procedure to get wrong.
Lead acid removal: six steps, two of which get skipped
- Remove the rear underhood apron.
- Disconnect 12V power using the 12V/LV Power procedure. The order matters more than the battery itself, and it is covered further down.
- Disconnect the vent tube hose from the LH side of the battery.
- Remove the positive terminal cover, loosen the positive lead nut at 6 Nm and take the lead off the battery.
- Remove the 12V battery strap.
- Lift the battery out, then write the last six digits of the VIN on the removed battery so it can be identified later.
Li-Ion removal: recover before you condemn
The first line of the Li-Ion section is a note that most shops never read: the Li-Ion low voltage battery may not need to be replaced at all, and recovery should be attempted first. That recovery is its own operation, the LV battery recover routine (correction code 17010008, 0.06 hours), backed by Toolbox article 6249900.
It is not a one-click fix. Three preconditions must be true or the routine will run and change nothing:
- The high voltage system has to be healthy and supporting the car: in Service Mode > Low Voltage > Power Distribution the PCS DCDC Support Status must read Active.
- The battery connector must be seated: the Li-Ion LV Battery ECPA status must read Closed.
- The battery MOSFET status must read Closed, shown in green.
If the MOSFET reads Open in orange, the car will also be logging VCFRONT_a478_LVBMS_MOSFET_Open. In that case run Close MOSFET > Run and let it complete. If that still does not recover the battery, connect the Tesla LV Li-Ion battery charger, recover it, and then repeat the routine. Only after all of that does replacement make sense.
Once the decision is made, Li-Ion removal is: remove the HEPA filter, disconnect LV power, wait two minutes for the electrical system to discharge, remove the three mounting bolts and lift the battery out.
Install: the open circuit voltage gate
Before a new battery goes in, the manual puts a hard gate on it. Measure the open circuit voltage: above 12.6V, install it. Between 12.4V and 12.6V, recharge it first. Below 12.4V, discard it. A battery that has sat on a shelf for a year can fail this test, which is why the check belongs in the job card rather than in someone’s memory.
Configuration: the part nobody bills for
- Lead acid type change: swapping a Clarios (Varta) battery for an AtlasBX, or the reverse, requires vehicle software 2023.32 or newer plus a configuration update: Service Mode > Low Voltage > Power Distribution > Change Battery Type, select the installed type, then Change Battery Type to Selected > Run. The update is a separate activity with its own correction code, 91022407, added to the same service visit.
- Li-Ion: connect LV power, bring the car up, unlock the gateway, then Service Mode > Low Voltage > Power Distribution > battery icon > Learn new battery > Run. Vehicle firmware must be 2023.44 or later. When it completes, the MOSFET and ECPA will show Closed. If the replacement is a CATL_LI_ION part, vehicle software must then be reinstalled as a separate step.
- HW4 compatibility: the manual states that both the silver-cased NMC Li-Ion battery and the black-cased LFP Li-Ion battery are compatible, so parts stock does not have to match casing colour.
- Verify the stored configuration afterwards: Service UI > Low Voltage > Power Distribution > Li-Ion LV battery > Config.
The disconnect order is where cars actually get damaged
The 12V/LV Power page carries a warning that is easy to skim past: failure to follow the exact order of steps may cause permanent damage to the car computer. The rules that matter in the bay:
- Before disconnecting, make sure the windows are not moved for at least one minute (a caution added 2025-10-30). Power the climate control off and wait at least 30 seconds.
- Vehicle in Park, all doors open, windows down, and a shop towel passed halfway through each rear door striker so the latches cannot secure. Closed doors can produce a lockout.
- Lead acid order: negative cable off first, then the first responder loop at the top of the RH shock tower (slide the red locking tab back, press the black tab, disconnect). On reassembly the first responder loop goes back before the negative cable.
- Multimeter sanity check: on a lead acid car, a reading below 10V or above 14V at the battery terminals means the meter is not measuring reliably and must not be used. On a Li-Ion car the valid window is 13 to 16V.
- Measure the LV busbar at the ancillary bay DC passthrough: below 1V you may continue; above 10V wait two minutes and measure again; if it is still above 10V the PCS is still supporting the low voltage system and the job should be escalated instead of continued.
- Disconnecting low voltage does not prove high voltage is gone. Any HV work still requires the Vehicle HV Disablement Procedure afterwards.
Four mistakes that come back as comebacks
- Treating it as a plain battery swap. No routine, no configuration, car starts fine and the state-of-charge logic is wrong for days.
- Skipping the open circuit voltage check. A 12.4V battery goes in and the customer is back tomorrow.
- Replacing a Li-Ion battery without attempting recovery. The manual says recover first; skipping it bills 0.18 hours for what may be a 0.06 hour job and scraps a serviceable part.
- Improvising the disconnect order. First responder loop before the negative cable, or moving windows inside the one minute window, is how control modules get hurt.
Customer complaint to first check
| What the customer says | What to check first |
|---|---|
| “It will not start after two days parked” | Identify the battery type first. On a Li-Ion car, read MOSFET and ECPA status and look for a478 before deciding recover or replace. |
| “The range display is wrong since the battery was changed” | Was Learn new battery run, and was the configuration updated for the actual part number? |
| “Another shop changed the battery and now it throws errors” | Was the fitted battery a different type, and was correction code 91022407 added? |
| “The doors locked themselves / a window is stuck” | Was the disconnect procedure followed, including the shop towels, windows down and the one minute rule? |
When to stop and bring someone in
Three situations end the job: the LV busbar still reads above 10V after the two minute wait, because the PCS is still powering the low voltage side and that is an HV system problem; both Close MOSFET and charger-based recovery fail, which means the battery has switched off internally; or the configuration write does not take after a type change. None of these get better with another attempt in the bay.
Stuck on a Fault Code or a Locked Module?
Our technicians work with Chinese OEM diagnostic tools every day. Send us the VIN and the fault codes — we’ll tell you exactly what to check, in what order, and what it costs.
Need the Parts?
We source OEM and OEM-equivalent parts for Chinese EVs and ship worldwide — brake pads, coolant pumps, charge ports, sensors and more.
Source
Summarised and rewritten from the Tesla Model Y service manual pages 12V/LV Battery (Remove and Replace) (correction codes 17011202 / 17011232, 0.18), 12V/LV Power (Disconnect and Connect) (17010200 / 17010410, 0.12) and LV Battery – Recover (Restore) (17010008, 0.06), revision dates 2023-09-06 to 2026-09-22 inclusive. Torque values, revision notes and routine names are quoted from those pages; nothing here is inferred.